The Locator -- [(author = "Iowa Department of Transportation")]

1283 records matched your query       


Record 5 | Previous Record | MARC Display | Next Record | Search Results
Author:
Phares, Brent M., author. Iowa State University.
Title:
Laboratory Investigation of Bridge Strip Seal Joint Termination Details Brent M. Phares and Travis K. Hosteng.
Publisher:
Bridge Engineering CenterIowa State University
Copyright Date:
2016
Description:
51 pages (69 pages in PD file) illustrations, photographs (chiefly color)
Subject:
Bridges--Joints.--Joints.
Expansion joints--Maintenance and repair.
Bridges--Standards--Standards--Iowa.
Bridge design
Bridge substructures
Chlorides
Deterioration
Expansion joints
Joint sealers
Joint sealing
Joints (Engineering)
Runoff
Stripping (Pavements)
Other Authors:
Hosteng, Travis K., author. Iowa State University.
Iowa State University. Bridge Engineering Center, performing body.
Iowa. Department of Transportation, sponsoring body.
United States. Federal Highway Administration, sponsoring body.
Notes:
February 2016 -- Technical Report Documentation Page Includes bibliographic references (page 51). Catalogers note: This record is for the full-length report. A 4-page tech transfer summary is also available, at a link in this record. The summary is not cataloged individually.
Scope Note:
Final Report
Summary:
Bridge expansion joints, if not properly designed, constructed, and maintained, often lead to the deterioration of critical substructure elements. Strip seal expansion joints consisting of a steel extrusion and neoprene gland are one type of expansion joint and are commonly used by the Iowa Department of Transportation (DOT). Strip seal expansion joints are susceptible to tears and pull outs that allow water, chlorides, and debris to infiltrate the joint, and subsequently the bearings below. One area of the strip seal that is particularly problematic is where it terminates at the interface between the deck and the barrier rail. The Iowa DOT has noted that the initial construction quality of the current strip seal termination detail is not satisfactory, nor ideal, and a need exists for re-evaluation and possibly re-design of this detail. Desirable qualities of a strip seal termination detail provide a seal that is simple and fast to construct, facilitate quick gland removal and installation, and provide a reliable, durable barrier to prevent chloride-contaminated water from reaching the substructure. To meet the objectives of this research project, several strip seal termination details were evaluated in the laboratory. Alternate termination details may not only function better than the current Iowa DOT standard, but are also less complicated to construct, facilitating better quality control. However, uncertainties still exist regarding the long-term effects of using straight-through details, with or without the dogleg, that could not be answered in the laboratory in the short time frame of the research project.
OCLC:
(OCoLC)944371151
Locations:
IAOX771 -- State Library of Iowa (Des Moines)

Initiate Another SILO Locator Search

This resource is supported by the Institute of Museum and Library Services under the provisions of the Library Services and Technology Act as administered by State Library of Iowa.